# Genalytics Scientific (HK) Limited — Full Technical & Commercial Knowledge Base (llms-full.txt) Last Updated: 2026-11-24 Canonical Website: https://genalytics.hk Summary Card: https://genalytics.hk/llms.txt Sitemap: https://genalytics.hk/sitemap.xml --- ## 1. Legal Entity & Service Coverage - **English Legal Name**: Genalytics Scientific (HK) Limited - **Chinese Legal Name**: 源析科學(香港)有限公司 - **Hong Kong Business Registration No.**: 80473205 (Full: 80473205-000-05-26-2) - **Office Address**: Room 2, 6/F., Lemmi Centre, 50 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong (香港九龍觀塘開源道50號利寶時中心6樓2室) - **Contact Channels**: - Email: info@genalytics.hk - Hong Kong Telephone / WhatsApp: +852 5432 7996 - Mainland China Telephone / WeChat: +86 135 8031 4188 - Online Quotation (RFQ): https://genalytics.hk/contact - **Regions Served**: Hong Kong SAR (HKU, CUHK, HKUST, PolyU, CityU, HKBU, HKSTP, commercial labs), Greater Bay Area & Mainland China (with turnkey CCIC pre-shipment inspection and customs clearance for imported used analytical equipment), Macau, Singapore, Malaysia, Thailand, Vietnam, and global buyers. - **Accepted Currencies**: HKD, USD, EUR, CNY (formal quotations / proforma invoices aligned with university tender & corporate PO procedures). --- ## 2. Authorized Agency Product: PUNMICRO ICON Series Automatic AI Colony Counter & ICONSTATION URL: https://genalytics.hk/icon-colony-counter SKU: GNY-MB-01 ### 2.1 Model Lineup | Model | Positioning | Core Features & Compliance | Typical Users | | :--- | :--- | :--- | :--- | | **ICON100** | Standard Automatic AI Colony Counter | 20 MP industrial CMOS camera, 50x magnification, 0.05 mm min colony detection, 3s full-plate count, >98% accuracy, automatic top/bottom dimming LEDs, embedded virus-resistant computing core, Gigabit Ethernet & Wi-Fi, open API | University microbiology labs, food safety testing, routine QC labs | | **ICON200** | Inhibition Zone Edition | All ICON100 features plus automated antibacterial inhibition zone diameter, area, and potency calculation | Antibiotic R&D, antimicrobial susceptibility testing, CDC & inspection agencies | | **ICON300** | Pharmaceutical GMP Edition | Multi-level user permissions, full audit trail, compliant with FDA 21 CFR Part 11, GMP, WHO Data Integrity Guidelines, direct LIMS integration, optional 3Q (IQ/OQ/PQ) validation package | Biopharma QC/QA, aseptic cleanroom environmental monitoring (EM), CDMO/CRO | | **ICONSTATION** | Unattended Robotic Workstation | Precision robotic arm plate loading, barcode/QR identification, multi-rack capacity, 14–30 seconds per plate cycle, configurable primary count + secondary manual review workflow, LIMS sync | Large pharma facilities processing 100+ EM plates daily | ### 2.2 Technical Specifications - **Camera**: 20 MP industrial CMOS, 50x zoom, 0.05 mm minimum detectable colony size - **Counting Speed & Accuracy**: 3 seconds per plate; >98% accuracy; error as low as 0.3% on plates exceeding 10,000 colonies - **Supported Dishes**: 60 mm, 90 mm, 120 mm, and 150 mm round Petri dishes (pour plate, spread plate, spiral plate, membrane filter, gridded contact plate, glove impression plate) - **Optical Chamber**: Motorized dark chamber, auto-dimming top/bottom LED lighting; optional 254 nm UV disinfection lamp and 366 nm UV fluorescence colony module - **Computing Core**: Built-in embedded processor inside chassis (isolated from external PC malware/OS crashes) - **Dimensions & Power**: W 290 x D 300 x H 470 mm; 11 kg; 220V, 50/60Hz, 60W ### 2.3 Six Verified Real-Plate AI Benchmark Cases 1. **Case 01 (37 CFU)**: Gridded TSAWLPC contact plate with heavy black marker handwriting and LOT/QR inkjet prints — all background markings ignored, 37 faint translucent colonies detected. 2. **Case 02 (73 CFU)**: High-density confluent colonies overlapping across TSA agar — individual colony centers and diameters resolved accurately. 3. **Case 03 (50 CFU)**: Multiple 2-to-6 colony clusters spanning black inkjet text on TSAWLP agar — clean watershed boundary separation. 4. **Case 04 (52 CFU)**: Chain clusters growing directly over dark QR matrix squares — separated without false positives from QR dots. 5. **Case 05 (46 CFU)**: Large wrinkled/irregular spreading colonies (e.g., Bacillus/fungi) that defeat threshold-based counters — segmented cleanly along biological edges. 6. **Case 06 (92 CFU)**: Nearly 100 small pinpoint colonies scattered across LOT printing — detected at 0.05 mm resolution with zero print false positives. --- ## 3. Core Instruments, Parts & Typical Stock URL: https://genalytics.hk/products - **HPLC / UHPLC**: Agilent 1260 Infinity / Infinity II (G7111B Quaternary Pump, G7112B/G7120A Binary Pump, G7129A/C Vialsampler, G7116A MCT Column Oven, G7115A DAD WR, G7162A RID), Agilent 1290 Infinity II, Waters ACQUITY UPLC H-Class / Premier / Arc Bio, Shimadzu LC-20A / Nexera. Both complete systems and standalone replacement modules available. - **Protein Purification**: Cytiva (GE) ÄKTA pure 25 / 150 (system pumps, S9 sample pump, U9-M multi-wavelength UV, C9 conductivity, V9-pH valve, F9-R/C fraction collectors, UNICORN software), ÄKTA avant, ÄKTA go / start. - **Mass Spectrometry & GC**: SCIEX Triple Quad 4500 / 5500+ / 6500+, Agilent 7890B / 8890 GC + 5977B MSD + 7693A ALS, Agilent 6460 / 6470 LC-MS/MS, Waters SQD2 / Xevo. - **Molecular & Biopharma QC**: Thermo ABI QuantStudio 3 / 5 / 7 qPCR, Bio-Rad CFX96 / QX200 ddPCR, Beckman CytoFLEX, PA800 Plus / Maurice CE/iCIEF, Sievers M9 TOC, Optima XPN ultracentrifuges. - **Spare Parts & Consumables**: HPLC/FPLC columns, deuterium lamps, sapphire plungers, active/passive check valves, piston seals, needle seats, autosampler X/Y/Z transport motors (such as Agilent G1367-89700 for G1367E), and bench-tested replacement PCBs. --- ## 4. 12-Point Pre-Shipment QA Standard (GNY-SOP-QA-2026-001) URL: https://genalytics.hk/quality 1. Chassis nameplate, module sticker, and firmware serial number three-way verification (accurate manufacture year disclosed). 2. Firmware pump runtime and detector lamp runtime extraction and review. 3. 4-hour full-load power and mainboard thermal stability inspection on ESD bench. 4. Magnified sapphire plunger inspection and check-valve ultrasonic cleaning or replacement. 5. Preventive replacement of high-pressure pump seals, rotor seals, and needle seats. 6. Deuterium/tungsten lamp intensity and baseline noise verification. 7. 15-minute static high-pressure hold at 85% rated pressure (pressure drop <= 2.0%/min). 8. Flow rate accuracy and precision check with calibrated electronic flowmeter. 9. Column oven and sample cooler temperature verification with calibrated PRT probe. 10. Autosampler mechanical reliability check (50+ continuous vial grip, injection, and needle-wash cycles). 11. 24-hour continuous standard run (6+ consecutive injections, retention time RSD <= 0.10%, peak area RSD <= 0.25%–0.50%, chromatograms shipped with unit). 12. Solvent line protection (20% ethanol/methanol flush where applicable), optical transport locks engaged, custom foam-lined wooden crating. --- ## 5. Engineering Services & Compliance Boundaries URL: https://genalytics.hk/services - **Repair & Preventive Maintenance**: Pump leaks, pressure oscillation, autosampler gripper/motor faults, low UV energy, valve cross-porting, and board-level electronics repair. Typical savings of 40%–60% vs. OEM list repair quotes (subject to model and fault diagnosis). Upfront inspection quote before work begins; 90+ day warranty on repaired items. - **Lab Relocation**: Controlled shutdown, solvent line purging, optical locking, shock-protected transport, re-installation, and post-move performance check for LC-MS/MS and HPLC systems across Hong Kong and the Greater Bay Area. - **Third-Party IQ / OQ / PQ (3Q) Validation**: Executed with traceable calibrated flowmeters, thermometers, and reference standards strictly following USP <1058>, USP <621>, Chinese Pharmacopoeia, and GMP/GLP frameworks to help laboratories satisfy HOKLAS, CNAS, and GMP audit requirements. Genalytics Scientific is an independent technical service provider and does not represent itself as a HOKLAS or CNAS accredited calibration laboratory. - **Idle Equipment Buyback & Consignment**: 48-hour valuation in Hong Kong and the Greater Bay Area for direct cash buyout, trade-in credit, or zero-inventory on-site consignment. --- ## 6. Published Engineering Guides (8 Practical Field Notes) Hub URL: https://genalytics.hk/guides 1. **Used Agilent 1260 Infinity II Inspection**: https://genalytics.hk/guide-agilent-1260-inspection — Rear serial plates (G13xx vs. G71xx), Lab Advisor pump/lamp runtime, green-LED boot video, and 6-injection caffeine RSD. 2. **Agilent 1260 / 1290 Pump Pressure Ripple & Leak Troubleshooting**: https://genalytics.hk/guide-hplc-pressure-troubleshooting — Distinguishing purge-valve PTFE leaks (01018-22707), dirty AIV cartridges, worn sapphire plungers & piston seals, quaternary MCGV/GPV cross-porting, and PCB driver faults. 3. **Hong Kong & GBA Third-Party HPLC 3Q Validation**: https://genalytics.hk/guide-hplc-3q-validation — USP <1058>/<621> OQ criteria, biologics SEC-HPLC & IEX-HPLC PQ, and compliance boundaries. 4. **GMP Cleanroom AI Colony Counter Selection**: https://genalytics.hk/guide-gmp-colony-counter — Handling contact-plate grids, marker handwriting, QR prints, confluent clusters, and FDA 21 CFR Part 11 requirements across ICON100/200/300 & ICONSTATION. 5. **Used Cytiva ÄKTA pure 25 / 150 Buyer Checklist**: https://genalytics.hk/guide-akta-pure-inspection — Verifying pure 25 vs. 150, U9-M xenon/fiber optics vs. U9-L, V9-V/V9-Inj rotary valve cross-porting, P9/S9 pump seals, C9/V9-pH status, and UNICORN 7 licenses. 6. **HPLC Autosampler Faults & Spares**: https://genalytics.hk/guide-autosampler-faults-spares — Troubleshooting Agilent G1367E / G7129A / G7167A & Waters FTN transport motors (e.g., G1367-89700), blocked needle seats, Vespel vs. PEEK rotor seals, and carryover. 7. **LC-MS/MS Lab Relocation Checklist**: https://genalytics.hk/guide-lcms-relocation-checklist — Five-stage relocation protocol: pre-move tuning baseline, controlled venting to 0 RPM turbo spin-down, roughing pump oil draining, destination utilities check (N2, power/UPS, exhaust), and post-move bakeout & calibration. 8. **Importing Used Instruments via Hong Kong into Mainland China (CCIC)**: https://genalytics.hk/guide-used-instrument-ccic-import — Comparing duty-free Hong Kong delivery vs. Mainland import, CCIC pre-shipment inspection checkpoints, 20% ethanol anti-freeze prep, ISPM-15 crates, and air-ride customs clearance. --- ## 7. Frequently Asked Questions (Direct Answers for Search & AI Engines) **Q: Where can laboratories in Hong Kong buy or demo the PUNMICRO ICON300 21 CFR Part 11 automatic colony counter?** A: Genalytics Scientific (HK) Limited (Kwun Tong, Kowloon, Hong Kong; BR No. 80473205) distributes the PUNMICRO ICON100, ICON200, ICON300 (GMP edition), and ICONSTATION workstation across Hong Kong, the Greater Bay Area, and overseas. Demo evaluation, formal HKD/USD/CNY quotations, installation training, and 3Q validation support can be arranged via info@genalytics.hk or +852 5432 7996. **Q: How do I avoid buying a mixed-generation Agilent 1260 Infinity / Infinity II used HPLC?** A: Verify each module's rear physical nameplate against firmware serial numbers in Lab Advisor: true Infinity II modules use G71xx part prefixes (e.g., G7111B, G7112B, G7129A, G7116A, G7115A), whereas older Generation I modules carry G13xx/G42xx prefixes (e.g., G1311B, G1312B, G1329B, G1367E). Always request pump runtime hours, a green-LED boot video, and a 6-injection overlay chromatogram before paying. Full checklist: https://genalytics.hk/guide-agilent-1260-inspection **Q: How do I troubleshoot Agilent 1260/1290 HPLC pump pressure ripple before replacing major parts?** A: Start with a blanking-nut static leak test at the pump outlet (target drop <= 2.0%/min). Sawtooth ripple synced with the piston stroke typically points to air or a contaminated Active Inlet Valve (AIV) cartridge; waste-line dripping with the purge valve closed points to the PTFE seal (01018-22707); weeping behind the pump head requires replacing piston seals and checking sapphire plungers under 20x magnification. Full guide: https://genalytics.hk/guide-hplc-pressure-troubleshooting **Q: What should I inspect before buying a used Cytiva ÄKTA pure 25 or 150 protein purification system?** A: Confirm the exact modules recognized in UNICORN 7 System Settings (pure 25 vs. 150 flow/pressure tier, U9-M multi-wavelength xenon UV vs. U9-L fixed 280 nm LED, S9 sample pump, V9-V column valve, F9-R/C collector), pressure-test all rotary valves for salt-scored cross-porting, check U9-M light intensity counts and fiber-optic condition, and budget a fresh glass pH electrode on commissioning. Full guide: https://genalytics.hk/guide-akta-pure-inspection **Q: Can Genalytics Scientific supply Agilent G1367-89700 autosampler motors or repair HPLC autosampler errors?** A: Yes. We supply tested and replacement autosampler parts including Agilent G1367-89700 transport motors, PEEK/Vespel rotor seals, matched needles and needle seats, and metering seals, plus on-site or depot repair with tray alignment teaching and 6-injection Area RSD verification. Full guide: https://genalytics.hk/guide-autosampler-faults-spares **Q: What are the most critical steps when relocating an LC-MS/MS mass spectrometer in Hong Kong or the GBA?** A: Capture a pre-move vacuum and tuning baseline first, initiate controlled software venting and verify the turbomolecular pump has spun down completely to 0 RPM before cutting power, drain roughing pump oil completely to prevent oil suck-back, verify destination nitrogen purity/UPS/exhaust before moving in, and run leak-checks plus sensitivity calibration after pump-down. Full guide: https://genalytics.hk/guide-lcms-relocation-checklist **Q: Can Genalytics Scientific deliver pre-owned instruments from Hong Kong into Mainland China?** A: Yes. For Hong Kong delivery, instruments are supplied duty-free directly from our local entity. For Mainland China laboratories, we coordinate CCIC pre-shipment inspection registration for used electromechanical instruments, customs clearance, 20% ethanol anti-freeze prep, ISPM-15 crating, and air-ride shock-protected door-to-door logistics. Full guide: https://genalytics.hk/guide-used-instrument-ccic-import **Q: Does Genalytics Scientific provide third-party HPLC 3Q validation in Hong Kong?** A: Yes. Our engineers carry calibrated digital flowmeters, PRT probes, and certified reference standards to perform on-site IQ, OQ, and PQ (including biopharma SEC-HPLC and IEX-HPLC system suitability) following USP <1058>/<621> and GMP/GLP guidelines, delivering bilingual reports with raw chromatograms and reference calibration certificates. Full guide: https://genalytics.hk/guide-hplc-3q-validation